A15
Herz Room Thermostat / Control Signal Fault

Boiler shows A15, no response to room thermostat, heating stays off

Advertisements

Possible Causes

Open circuit in room thermostat wiring, faulty Herz room controller, incorrect parameter settings on PCB, broken low-voltage terminal block

How to Fix / Troubleshooting

Safety: Isolate power before accessing control terminals.

  • Check controller: Ensure the Herz room thermostat or controller has power, correct time, and is calling for heat.
  • Inspect wiring: At the boiler, verify that the room thermostat wires are firmly connected and not damaged.
  • Bridge test: Temporarily bridge the room thermostat terminals at the boiler (if allowed by Herz manual). If the boiler starts, the external control or wiring is faulty.
  • Reconfigure parameters: Check that the boiler is set to accept external control (e.g., on/off or BUS mode) according to the Herz installation manual.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Herz room thermostat / controller