A15
Herz
Room Thermostat / Control Signal Fault
Boiler shows A15, no response to room thermostat, heating stays off
Advertisements
Possible Causes
Open circuit in room thermostat wiring, faulty Herz room controller, incorrect parameter settings on PCB, broken low-voltage terminal block
How to Fix / Troubleshooting
Safety: Isolate power before accessing control terminals.
- Check controller: Ensure the Herz room thermostat or controller has power, correct time, and is calling for heat.
- Inspect wiring: At the boiler, verify that the room thermostat wires are firmly connected and not damaged.
- Bridge test: Temporarily bridge the room thermostat terminals at the boiler (if allowed by Herz manual). If the boiler starts, the external control or wiring is faulty.
- Reconfigure parameters: Check that the boiler is set to accept external control (e.g., on/off or BUS mode) according to the Herz installation manual.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Herz room thermostat / controller