Herz

Herz Boilers Error Codes

Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.

Advertisements
A01
Boiler locks out, burner does not ignite, red fault LED on, display shows A01
Ignition Failure / No Flame Detected
A02
Boiler starts, flame appears briefly then shuts down and locks out with code A02
Flame Loss During Operation
A03
Boiler locks out shortly after start, display shows A03, overheat LED may be lit
Safety Temperature Limiter (STB) Tripped / Overheat
A04
Boiler does not start, display shows A04, no fan operation
Fan / Air Pressure Fault
A05
Boiler locks out with A05, fan runs but no ignition sequence starts
Air Pressure Switch Not Proving
A06
Boiler shows A06, intermittent ignition, sometimes noisy start
Ignition Spark Fault
A07
Boiler display shows A07, no heating or hot water, pump may run briefly then stop
Flow Temperature Sensor Fault (NTC Flow Open/Short)
A08
Boiler shows A08, temperature reading is fixed or unrealistic, boiler may cycle rapidly
Return Temperature Sensor Fault (NTC Return Open/Short)
A09
Boiler locks out with A09, DHW temperature unstable or not reaching setpoint
DHW Temperature Sensor Fault (NTC DHW)
A10
Boiler shows A10, no heating, pump may run continuously
Flow Switch / Flow Sensor Fault
A11
Boiler display shows A11, burner stops, fan may continue to run
Flue Gas Temperature Too High
A12
Boiler shows A12, will not start, sometimes after power surge
Control Board Internal Fault
A13
Boiler shows A13, external safety circuit open, no operation
External Safety Chain Open (e.g., limit stats, external interlocks)
A14
Boiler shows A14, burner output limited, may not reach set temperature
Outdoor Sensor Fault / Weather Compensation Error
A15
Boiler shows A15, no response to room thermostat, heating stays off
Room Thermostat / Control Signal Fault
A16
Boiler shows A16, frequent short cycling, limited modulation
Modulation / Gas Valve Control Fault
A17
Boiler shows A17, pump runs but burner does not start, system may be cold
Low Water Pressure / Water Shortage
A18
Boiler shows A18, pressure rises rapidly during heating, safety valve may discharge
Overpressure / Expansion Fault
A19
Boiler shows A19, condensate pump runs frequently or boiler shuts down
Condensate Drain / Pump Fault
A20
Boiler shows A20, burner stops unexpectedly, flue gas safety device activated
Flue Gas Safety Thermostat Trip
A21
Boiler shows A21, burner output limited, fan speed abnormal
Fan Speed / Tachometer Fault
A22
Boiler shows A22, DHW priority fault, heating may be disabled
DHW Flow Switch / Turbine Fault
A23
Boiler shows A23, communication error with remote controller or cascade manager
BUS Communication Fault
A24
Boiler shows A24, burner stops, system temperature rises unexpectedly
Pump Fault / No Circulation
A25
Boiler shows A25, burner locked out, gas supply appears normal
Gas Valve Safety Shutoff Fault
A26
Boiler shows A26, system temperature sensor mismatch, erratic operation
Sensor Calibration / Mismatch Fault
A27
Boiler shows A27, burner stops during DHW draw, temperature overshoots
Plate Heat Exchanger Blockage / DHW Overheat
A28
Boiler shows A28, cascade system not responding correctly
Cascade Control / Master-Slave Communication Fault
A29
Boiler shows A29, burner output limited, oxygen level control fault (if equipped)
Lambda / O2 Sensor Fault
A30
Boiler shows A30, internal clock or scheduling not working
Internal Clock / Backup Battery Fault
Symptom
Boiler cycles on and off rapidly without reaching room temperature
Short Cycling / Oversized Boiler or Control Issue
Symptom
Boiler does not respond to any buttons on the front panel
User Interface / Keypad Failure
Symptom
Boiler emits a burning smell or plastic smell during operation
Overheating Electrical Component / Insulation
Symptom
Boiler fan runs continuously even when there is no heat demand
Post-Purge / Control Stuck
Symptom
Boiler flue terminal shows white staining and excessive condensate dripping
Condensate Management / Flue Slope Issue
Symptom
Boiler frequently loses pressure and needs topping up
Chronic Pressure Loss
Symptom
Boiler leaking water from underneath the casing
General Water Leak in Hydraulic Circuit
Symptom
Boiler makes loud banging or knocking noises when starting or stopping
Kettling / Hydraulic Shock
Symptom
Boiler produces a whistling or high-pitched noise during firing
Combustion Resonance / Gas Flow Noise
Symptom
Boiler runs but radiators remain cold or only lukewarm
Poor Circulation / Balancing Issue
Symptom
Boiler starts normally but shuts down after a few minutes without error code
Intermittent Overheat or Control Interruption
Symptom
Hot water temperature fluctuates between hot and cold during use
DHW Temperature Instability
Symptom
Radiators get hot even when there is no call for heating
Unwanted Heating / Valve Bypass