Junkers Chronic pressure loss

Boiler frequently loses pressure and needs topping up

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Leaking radiators or pipework, Faulty expansion vessel, Dripping safety relief valve, Micro-leaks inside boiler components

How to Fix / Troubleshooting

Safety: Do not repeatedly overfill the system above the recommended pressure.

  • Visual leak check: Inspect all radiators, valves, and visible pipework for damp patches or staining.
  • Check safety valve outlet: Look at the discharge pipe outside; if it is wet or dripping, the safety valve may be passing.
  • Expansion vessel test (technician):
    • Isolate and drain pressure from the boiler.
    • Measure the air charge at the expansion vessel Schrader valve; recharge to the value specified by Junkers if low.
    • Replace the expansion vessel if the diaphragm has failed.
  • System pressure monitoring: Mark the gauge and monitor over several days to locate intermittent losses.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Expansion Vessel
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements