Junkers
Junkers Boilers Error Codes
Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.
Advertisements
A2
Boiler does not start; display shows A2 and burner symbol does not appear
No flame detection on start-up
A3
Boiler locks out with A3; fan runs briefly then stops, burner does not ignite
Flue gas temperature sensor fault / overtemperature
A7
Boiler shows A7; domestic hot water temperature is unstable or incorrect
DHW temperature sensor (NTC) fault
A8
Boiler displays A8 and does not respond to room thermostat commands
Communication fault with room controller / sensor
A9
Boiler shows A9; heating flow temperature reading is implausible or boiler overheats quickly
Flow temperature sensor (NTC) fault
C1
Boiler displays C1; fan starts but ignition does not proceed or boiler shuts down
Fan speed / air pressure fault
C6
Boiler shows C6; fan runs erratically or at incorrect speed
Fan speed control / feedback error
C7
Boiler displays C7; no fan operation detected when there is a heat demand
Fan not running
D3
Boiler shows D3; burner stops and boiler remains off for a defined waiting time
Anti-cycling / burner blocking time active
E2
Boiler displays E2; flow temperature sensor error
Flow NTC sensor open or short circuit
E3
Boiler shows E3; return temperature sensor fault
Return NTC sensor open or short circuit
E5
Boiler displays E5; flue gas temperature too high or sensor fault
Flue gas overtemperature / flue NTC fault
E9
Boiler locks out with E9; overheating or dry-fire condition
Safety temperature limiter (STB) tripped / overheat
E9 (water pressure)
Boiler shows E9 or low-pressure symbol; boiler does not start
Low system water pressure
EA
Boiler shows EA; ignition failure or flame lost during operation
Ignition / flame loss fault
F0
Boiler shows F0; internal control fault
Control board hardware error
F1
Boiler displays F1; sensor supply or internal sensor error
Internal sensor / reference voltage fault
F7
Boiler shows F7; flame signal detected when burner should be off
False flame detection
H7
Boiler displays H7; service reminder or maintenance required
Service interval reached
P2
Boiler shows P2; hot water priority or pump overrun active
DHW priority / pump overrun mode
Symptom
Boiler condensate pipe dripping heavily or gurgling noises from condensate trap
Condensate drainage issue
Symptom
Boiler display works but no response to any buttons
Keypad / user interface failure
Symptom
Boiler emits smell of burning plastic or electrical overheating
Overheating electrical component
Symptom
Boiler emits smell of gas near the casing
Gas leak at boiler connections
Symptom
Boiler fan is very noisy during operation
Worn or unbalanced fan
Symptom
Boiler frequently loses pressure and needs topping up
Chronic pressure loss
Symptom
Boiler frequently trips the household circuit breaker or RCD
Electrical short or earth leakage
Symptom
Boiler ignition causes a loud bang (delayed ignition)
Delayed gas ignition
Symptom
Boiler leaking water from underneath the casing
Internal water leak
Symptom
Boiler makes loud banging or kettling noises during operation
Heat exchanger kettling / localised boiling
Symptom
Boiler runs but some radiators remain cold at the top
Air trapped in radiators
Symptom
Boiler runs continuously and overheats rooms even when thermostat is turned down
Boiler not responding to room thermostat
Symptom
Boiler starts then shuts down after a few seconds without showing a code
Short cycling / premature shutdown
Symptom
Boiler will not start at all; display is blank
No power / dead boiler
Symptom
Domestic hot water temperature fluctuates between hot and cold
Unstable DHW temperature control
Symptom
Radiators are cold but boiler appears to run and hot water works
No central heating circulation
| Error Code | Symptom | Fault Type | Guide |
|---|---|---|---|
| A2 |
Boiler does not start; display shows A2 and burner symbol does not appear
|
No flame detection on start-up | View Details |
| A3 |
Boiler locks out with A3; fan runs briefly then stops, burner does not ignite
|
Flue gas temperature sensor fault / overtemperature | View Details |
| A7 |
Boiler shows A7; domestic hot water temperature is unstable or incorrect
|
DHW temperature sensor (NTC) fault | View Details |
| A8 |
Boiler displays A8 and does not respond to room thermostat commands
|
Communication fault with room controller / sensor | View Details |
| A9 |
Boiler shows A9; heating flow temperature reading is implausible or boiler overheats quickly
|
Flow temperature sensor (NTC) fault | View Details |
| C1 |
Boiler displays C1; fan starts but ignition does not proceed or boiler shuts down
|
Fan speed / air pressure fault | View Details |
| C6 |
Boiler shows C6; fan runs erratically or at incorrect speed
|
Fan speed control / feedback error | View Details |
| C7 |
Boiler displays C7; no fan operation detected when there is a heat demand
|
Fan not running | View Details |
| D3 |
Boiler shows D3; burner stops and boiler remains off for a defined waiting time
|
Anti-cycling / burner blocking time active | View Details |
| E2 |
Boiler displays E2; flow temperature sensor error
|
Flow NTC sensor open or short circuit | View Details |
| E3 |
Boiler shows E3; return temperature sensor fault
|
Return NTC sensor open or short circuit | View Details |
| E5 |
Boiler displays E5; flue gas temperature too high or sensor fault
|
Flue gas overtemperature / flue NTC fault | View Details |
| E9 |
Boiler locks out with E9; overheating or dry-fire condition
|
Safety temperature limiter (STB) tripped / overheat | View Details |
| E9 (water pressure) |
Boiler shows E9 or low-pressure symbol; boiler does not start
|
Low system water pressure | View Details |
| EA |
Boiler shows EA; ignition failure or flame lost during operation
|
Ignition / flame loss fault | View Details |
| F0 |
Boiler shows F0; internal control fault
|
Control board hardware error | View Details |
| F1 |
Boiler displays F1; sensor supply or internal sensor error
|
Internal sensor / reference voltage fault | View Details |
| F7 |
Boiler shows F7; flame signal detected when burner should be off
|
False flame detection | View Details |
| H7 |
Boiler displays H7; service reminder or maintenance required
|
Service interval reached | View Details |
| P2 |
Boiler shows P2; hot water priority or pump overrun active
|
DHW priority / pump overrun mode | View Details |
| – |
Boiler condensate pipe dripping heavily or gurgling noises from condensate trap
|
Condensate drainage issue | View Details |
| – |
Boiler display works but no response to any buttons
|
Keypad / user interface failure | View Details |
| – |
Boiler emits smell of burning plastic or electrical overheating
|
Overheating electrical component | View Details |
| – |
Boiler emits smell of gas near the casing
|
Gas leak at boiler connections | View Details |
| – |
Boiler fan is very noisy during operation
|
Worn or unbalanced fan | View Details |
| – |
Boiler frequently loses pressure and needs topping up
|
Chronic pressure loss | View Details |
| – |
Boiler frequently trips the household circuit breaker or RCD
|
Electrical short or earth leakage | View Details |
| – |
Boiler ignition causes a loud bang (delayed ignition)
|
Delayed gas ignition | View Details |
| – |
Boiler leaking water from underneath the casing
|
Internal water leak | View Details |
| – |
Boiler makes loud banging or kettling noises during operation
|
Heat exchanger kettling / localised boiling | View Details |
| – |
Boiler runs but some radiators remain cold at the top
|
Air trapped in radiators | View Details |
| – |
Boiler runs continuously and overheats rooms even when thermostat is turned down
|
Boiler not responding to room thermostat | View Details |
| – |
Boiler starts then shuts down after a few seconds without showing a code
|
Short cycling / premature shutdown | View Details |
| – |
Boiler will not start at all; display is blank
|
No power / dead boiler | View Details |
| – |
Domestic hot water temperature fluctuates between hot and cold
|
Unstable DHW temperature control | View Details |
| – |
Radiators are cold but boiler appears to run and hot water works
|
No central heating circulation | View Details |