A2
Junkers
No flame detection on start-up
Boiler does not start; display shows A2 and burner symbol does not appear
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Gas supply closed or insufficient, Faulty ionisation electrode, Faulty gas valve, Faulty ignition control on main PCB
How to Fix / Troubleshooting
Safety first: Turn the boiler off at the main switch and isolate the gas supply before removing any covers. Only a Gas Safe / certified gas technician should work on gas-carrying components.
- Check gas supply: Ensure the gas cock under the Junkers boiler is fully open. Verify other gas appliances in the home work correctly. If not, contact your gas supplier.
- Reset the boiler: Use the reset button (often marked with a flame or reset symbol) and wait for a full ignition cycle. If A2 reappears, continue.
- Inspect flue terminal: From outside, make sure the flue is not blocked by leaves, snow, or debris, which can affect combustion.
- Check flame viewing window: If accessible without removing the sealed combustion cover, observe whether the burner lights briefly and then goes out. This indicates poor flame detection.
- Professional checks (technician only):
- Remove front cover and inspect the ionisation electrode for cracks, heavy oxidation, or incorrect gap; clean lightly with fine emery cloth and refit or replace.
- Measure ionisation current according to Junkers service manual; if low, replace the ionisation electrode and check burner surface for contamination.
- Verify correct gas pressure at the inlet and at the burner using a manometer; adjust or replace the gas valve if out of specification.
- Check wiring harness between electrode and control board for damage or loose connections.