A8
Junkers Communication fault with room controller / sensor

Boiler displays A8 and does not respond to room thermostat commands

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Disconnected or damaged bus cable, Incompatible or faulty Junkers room controller, Incorrect controller wiring on EMS/Bosch Heatronic bus, Faulty main PCB communication circuit

How to Fix / Troubleshooting

Safety: Turn off power before working on control wiring.

  • Check controller display: Verify that the Junkers room thermostat or controller powers up and shows no own error codes.
  • Inspect wiring: Remove the boiler front cover and check the low-voltage bus terminals (e.g., EMS/Heatronic). Ensure the polarity and terminal positions match the Junkers wiring diagram.
  • Look for damage: Trace the cable between boiler and controller for cuts, crushed sections, or signs of moisture ingress; repair or replace as needed.
  • Test with link: If allowed by the service manual, temporarily disconnect the controller and fit a test link or simple on/off thermostat to verify boiler response (technician only).
  • Controller reset: Reset the room controller to factory settings and reconfigure according to Junkers instructions.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Junkers Room Controller / EMS Bus Cable