Junkers
Short cycling / premature shutdown
Boiler starts then shuts down after a few seconds without showing a code
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Oversized boiler, Poor circulation, Faulty temperature sensor, Incorrect minimum power setting, Blocked filter
How to Fix / Troubleshooting
Safety: Repeated cycling can stress components; address the cause promptly.
- Check all radiators: Ensure enough radiators are open to absorb the boiler's minimum output.
- Bleed and balance: Bleed radiators and balance the system to improve flow.
- Clean filters: Clean any system or boiler-integrated filters/strainers.
- Technician tasks:
- Check NTC sensors for correct readings.
- Adjust boiler minimum output and pump settings via the service menu.
- Assess system design and consider adding a buffer or additional emitters if the boiler is significantly oversized.
Advertisements
Repair Difficulty
Medium
3/5
Advertisements