Possible Causes
Partially blocked plate heat exchanger, Faulty DHW NTC sensor, Inadequate minimum flow rate, Modulating gas valve not adjusting correctly
How to Fix / Troubleshooting
Safety: Risk of scalding; be cautious when testing hot water.
- Check flow rate: Open the hot tap fully; very low flow can cause cycling. Clean tap aerators and shower heads to improve flow.
- Set temperature: Adjust the DHW temperature setting on the Junkers control to a moderate value (e.g., 50–55°C) and retest.
- Technician actions:
- Clean or replace the plate heat exchanger if restricted by limescale.
- Test and replace the DHW NTC sensor if readings are unstable.
- Check gas valve modulation and burner pressure.