E20
Nibe Manual Reset Safety Thermostat Trip

Boiler shows internal overheat or safety thermostat trip, complete lockout

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Severely restricted water flow, Failed circulation pump, Limescale in heat exchanger, Faulty safety thermostat

How to Fix / Troubleshooting

Safety first: Allow the boiler to cool completely before attempting a reset. Surfaces and water may be extremely hot.

  • Check system pressure and valves: Ensure adequate pressure and that all isolation valves are open.
  • Bleed air and check pump: Remove air from the system and confirm the Nibe pump is running when there is a demand.
  • Locate reset button: Some Nibe boilers have a manual reset button on the safety thermostat behind the front cover. Press gently once to reset after cooling.
  • Do not repeatedly reset: Repeated trips indicate a serious underlying issue such as a blocked heat exchanger. Call a technician.
  • Professional descaling: In hard water areas, a Nibe technician may need to chemically descale or replace the primary heat exchanger.
Advertisements

Repair Difficulty

Hard 4/5