Nibe

Nibe Boilers Error Codes

Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.

Advertisements
E01
Boiler locked out, red fault lamp on, no heating or hot water
Ignition Failure Lockout
E02
Boiler attempts to start but shuts down with overheat alarm, flow temperature very high
Primary Circuit Overheat Trip
E03
Boiler shows flue/venting error, burner stops shortly after ignition attempt
Flue Gas Safety / Ventilation Fault
E04
Boiler displays low water pressure alarm, heating and hot water disabled
Low System Pressure
E05
Boiler shows high pressure alarm, pressure gauge above safe range, safety valve may discharge water
High System Pressure
E06
Boiler displays flow temperature sensor fault, burner does not start or cycles rapidly
Flow Temperature Sensor Failure
E07
Boiler displays return temperature sensor fault, poor modulation or lockout
Return Temperature Sensor Failure
E08
Boiler shows domestic hot water (DHW) sensor error, hot water temperature unstable or disabled
DHW Temperature Sensor Fault
E09
Boiler indicates outdoor sensor fault (for weather-compensated systems), heating curve not followed
Outdoor Temperature Sensor Failure
E10
Boiler shows fan speed or fan feedback error, burner does not ignite
Fan Speed Control / Air Pressure Fault
E11
Boiler displays flame loss during operation, repeated ignition attempts then lockout
Flame Supervision Fault
E12
Boiler shows communication error between main PCB and user interface or between boiler and Nibe accessory module
Internal Communication Fault
E13
Boiler indicates sensor short-circuit or over-temperature on flue gas sensor
Flue Gas Temperature Sensor Fault
E14
Boiler shows condensate fault or blocked condensate drain, unit may shut down
Condensate Drain Blockage
E15
Boiler indicates flow switch or flow sensor error, burner will not start
Insufficient Water Flow / Flow Switch Fault
E16
Boiler shows DHW flow sensor error, no hot water despite demand
DHW Flow Detection Fault
E17
Boiler indicates gas valve or gas modulation fault, no or unstable flame
Gas Valve Control Error
E18
Boiler shows power supply or mains frequency error, intermittent resets
Mains Supply / Power Quality Fault
E19
Boiler indicates sensor fault on heating circuit 2 or mixing circuit (if equipped)
Secondary Circuit Sensor Fault
E20
Boiler shows internal overheat or safety thermostat trip, complete lockout
Manual Reset Safety Thermostat Trip
Symptom
Boiler cycles on and off rapidly without reaching set temperature
Short Cycling
Symptom
Boiler display works but there is no response to heating or hot water demand
Demand Signal Failure
Symptom
Boiler does not start at all, display blank or unresponsive
No Power / Dead Boiler
Symptom
Boiler frequently goes into frost protection mode even when not particularly cold indoors
Incorrect Temperature Sensing / Control Logic
Symptom
Boiler frequently locks out and needs manual reset, with varying error messages
Intermittent Control or Sensor Issues
Symptom
Boiler frequently loses pressure over days or weeks without visible leaks
Chronic Pressure Loss
Symptom
Boiler is very noisy during operation (whining, grinding, or rattling)
Mechanical Noise / Wear
Symptom
Boiler leaking water from underneath the casing
Internal Water Leak
Symptom
Boiler makes loud banging or knocking noises when starting or stopping
Kettling / Hydraulic Shock
Symptom
Boiler or flue emits unusual smells (burning, chemical, or flue gas odour)
Overheating or Combustion Issue
Symptom
Boiler runs but hot water temperature fluctuates or goes cold during shower
Unstable DHW Temperature
Symptom
Boiler runs but radiators stay cold or only lukewarm
Poor Heating Performance
Symptom
Boiler runs continuously and overheats the house even when room thermostat is turned down
Control / Thermostat Fault
Symptom
Boiler’s condensate pipe drips constantly even when boiler is off
Condensate or System Water Passing
Symptom
Radiators upstairs are hot but downstairs are cold
Imbalanced or Sludged Heating Circuit