E11
Beko Trigger Switch / User Input Fault

Display shows E11 and the unit will not run the brush or suction when the handle trigger is pressed.

Advertisements

Possible Causes

Defective trigger microswitch in handle, Broken trigger lever, Disconnected trigger wiring, Faulty input circuit on PCB

How to Fix / Troubleshooting

Safety first: Unplug the carpet cleaner before opening the handle assembly.

  • 1. Inspect trigger mechanism: Check that the trigger moves freely and returns when released. If the plastic lever is cracked or broken, replace the handle/trigger assembly.
  • 2. Test trigger switch: Open the handle housing to access the microswitch. Use a multimeter in continuity mode to verify that the switch closes when the trigger is pulled. Replace the switch if it fails this test.
  • 3. Check wiring: Ensure the trigger switch wires are intact and firmly connected to the main harness. Repair any broken wires with proper connectors.
  • 4. PCB input test: If the switch and wiring are good, the input circuit on the PCB may not be detecting the trigger. In that case, replace the main PCB.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Handle Trigger Microswitch
Check Price on Amazon

We may earn a commission from links on this page.