Henry
Insufficient Extraction / Poor Airflow
Machine leaves carpets very wet, poor water extraction
Advertisements
Possible Causes
Blocked recovery tank filter, Air leak at wand or tool, Worn squeegee lips on floor tool, Overfilling solution on each pass
How to Fix / Troubleshooting
Safety: Unplug before cleaning filters or tools.
- Clean filters and tank:
- Wash the recovery tank filter and ensure the tank is free of sludge.
- Inspect floor tool:
- Check the rubber squeegee lips on the extraction tool.
- Replace the floor tool squeegee strip if worn, torn, or hardened.
- Check for air leaks:
- Ensure the hose-to-tool and hose-to-machine joints are tight.
- Adjust cleaning technique:
- Make one wet pass (spray + vacuum) followed by several dry passes (vacuum only) to remove excess moisture.
Advertisements
Repair Difficulty
Very Easy
1/5
Required Part
Floor Tool Squeegee Strip
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements