Rowenta No Power / Dead Appliance

Carpet cleaner will not power on at all; no lights or sounds.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blown plug fuse, Damaged power cord, Faulty main power switch, Open thermal fuse on control PCB

How to Fix / Troubleshooting

Safety first: Ensure the unit is unplugged before opening any covers. Do not bypass safety devices.

  • Verify supply: Test the wall outlet with another device. Check and replace the plug fuse with the correct rating if blown.
  • Inspect power cord: Look for cuts, burns, or crushed sections. Flex the cord gently near the plug and strain relief; if power is intermittent, replace the cord set.
  • Test power switch: Access the main rocker switch and check continuity when switched ON. Replace if it does not close.
  • Check internal thermal fuse: Some Rowenta models include a thermal fuse on the PCB or in-line with the motor. Test for continuity and replace only with the same temperature and current rating.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Power Cord
Check Price on Amazon