Rowenta
No Solution Spray
No water or cleaning solution sprays from the floor nozzle, but the motor runs normally.
Advertisements
Possible Causes
Empty or improperly seated clean water tank, Blocked spray nozzles, Airlock in solution line, Failed solution pump
How to Fix / Troubleshooting
Safety first: Unplug the unit and remove the tanks before working on the spray system.
- Check tank and solution mix: Fill the clean water/solution tank and ensure it clicks firmly into place. Confirm the outlet valve at the bottom opens when installed.
- Prime the system: With the tank installed, tilt the unit slightly back and hold the trigger for 30–60 seconds to purge air from the lines (if your model allows priming).
- Clean spray nozzles: Remove the floor nozzle and use a pin or soft brush to clear each spray jet. Rinse under warm water to dissolve detergent buildup.
- Inspect solution hose: Follow the hose from tank to pump and pump to nozzle. Straighten kinks and replace any hose that is collapsed or cracked.
- Listen for pump: When plugged in and trigger pulled, you should hear the pump buzz. If silent, the pump may be failed and require replacement.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Spray Nozzle Assembly
Check Price on Amazon