Rowenta Solution Dripping / Valve Not Closing

Solution continues to drip from the nozzle for several minutes after releasing the trigger.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Worn check valve in spray manifold, Debris in solenoid valve, Excessive line pressure due to high tank position, Cracked nozzle body

How to Fix / Troubleshooting

Safety first: Unplug and remove the clean water tank.

  • Relieve pressure: After use, turn the unit off and remove the tank to reduce pressure in the solution line.
  • Clean spray manifold: Remove the nozzle and rinse the spray bar and internal check valves with warm water to clear debris.
  • Inspect solenoid valve: If fitted, remove and flush the solenoid valve to ensure it closes fully.
  • Replace worn parts: If dripping persists, replace the spray manifold or solenoid valve assembly.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Spray Manifold
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements