Rowenta
Solution Dripping / Valve Not Closing
Solution continues to drip from the nozzle for several minutes after releasing the trigger.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Worn check valve in spray manifold, Debris in solenoid valve, Excessive line pressure due to high tank position, Cracked nozzle body
How to Fix / Troubleshooting
Safety first: Unplug and remove the clean water tank.
- Relieve pressure: After use, turn the unit off and remove the tank to reduce pressure in the solution line.
- Clean spray manifold: Remove the nozzle and rinse the spray bar and internal check valves with warm water to clear debris.
- Inspect solenoid valve: If fitted, remove and flush the solenoid valve to ensure it closes fully.
- Replace worn parts: If dripping persists, replace the spray manifold or solenoid valve assembly.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Spray Manifold
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements