VAX Platinum
Control Panel / Power Supply Instability
LED indicators on the control panel flicker or do not light consistently
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Loose control panel connector, Failing LEDs on panel, Fluctuating mains supply, Faulty low-voltage power supply on PCB
How to Fix / Troubleshooting
Safety first: Unplug the machine before accessing the control panel.
- Check mains outlet: Test the outlet with another appliance to rule out supply issues.
- Power reset: Unplug the machine for 5 minutes, then reconnect and test.
- Panel connection (advanced): Remove the control panel cover and reseat the ribbon cable or connector to the main PCB.
- Panel replacement: If specific LEDs have failed or flicker independently, the control panel may need replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Control Panel PCB
Check Price on Amazon