Possible Causes

Clogged floorhead spray bar, Kinked solution hose at base, Blocked internal check valve to floorhead, Mineral build-up from hard water

How to Fix / Troubleshooting

Safety first: Unplug the machine and remove the clean water tank before working on the floorhead.

  • Check hose tool spray: Confirm that the hose tool sprays correctly. This indicates the pump and main solution line are working.
  • Clean floorhead nozzles: Remove the floorhead (if detachable) and locate the spray bar. Use a pin or soft brush to clear each nozzle hole. Soak the spray bar in a 50/50 mix of white vinegar and warm water for 30 minutes to dissolve mineral deposits, then rinse thoroughly.
  • Inspect solution hose at base: Look for sharp bends or kinks where the solution hose enters the floorhead. Straighten or reposition as needed.
  • Flush system: Reassemble and run warm water (no detergent) through the system for several minutes to flush any remaining debris.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Floorhead Spray Bar