Vorwerk Poor Extraction / Inadequate Suction at Nozzle

Carpet cleaner leaves carpets excessively wet after cleaning.

Advertisements

Possible Causes

Blocked nozzle suction slot, Air leak at nozzle gasket, Clogged recovery path, Worn motor reducing suction

How to Fix / Troubleshooting

Safety: Unplug before cleaning the nozzle.

  • Clean nozzle: Remove the floor nozzle and rinse the suction slot under warm water. Use a soft brush to remove lint and hair.
  • Check gasket: Inspect the nozzle-to-body gasket for damage. Replace if flattened or torn.
  • Empty tank and filters: Ensure the recovery tank is not full and that filters are clean to maintain airflow.
  • Multiple passes: Use additional dry passes (suction only, no spray) to extract more water. If suction remains weak, the motor may be worn and require replacement.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Floor Nozzle Assembly
Check Price on Amazon

We may earn a commission from links on this page.