E15
Vorwerk Detergent Dosing Valve / Mixing System Fault

E15 error and the unit stops spraying detergent mixture correctly; water may spray without detergent.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Stuck detergent dosing valve, Blocked detergent line, Faulty dosing solenoid, Empty detergent reservoir

How to Fix / Troubleshooting

Safety: Unplug the cleaner and remove any detergent cartridges or reservoirs.

  • Check detergent level: Ensure the detergent reservoir or cartridge is not empty.
  • Flush detergent line: Run a tank of clean water only, activating the spray to flush detergent residue from the lines.
  • Clean dosing valve: If accessible, remove the dosing valve and soak it in warm water to dissolve dried detergent. Gently move the valve plunger to free it.
  • Solenoid test (advanced): A technician can test the dosing solenoid coil for correct resistance. Replace the valve/solenoid assembly if defective.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Detergent Dosing Valve
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements