E11
Zanussi Safety Interlock / Body Position Fault

Unit will not start cleaning cycle; E11 displayed indicating safety interlock not engaged

Advertisements

Possible Causes

Faulty handle position switch, Defective tilt sensor, Broken interlock tab on body or handle, Misaligned body shell preventing switch activation

How to Fix / Troubleshooting

Safety: Disconnect from mains before inspecting switches.

  • Check handle position: Ensure the Zanussi handle is fully lowered into the operating position. Some models will not run when fully upright.
  • Inspect interlock tabs: Look for broken plastic tabs or levers that press on micro-switches when the handle is lowered. Replace damaged body or handle parts if necessary.
  • Test micro-switch: Access the handle or base area where the interlock switch is located. Use a multimeter to test continuity when the handle is in the run position. Replace the switch if it does not change state.
  • Check tilt sensor (if fitted): Some models use a tilt sensor module. Ensure it is securely mounted and not damaged. Replace if faulty.
  • Reset and test: After repair, reassemble, plug in, and confirm that E11 is cleared and the unit starts normally when the handle is lowered.