Machine displays E07 and brewing stops; internal brew group does not move to correct position.
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety first: Turn off and unplug the machine before removing the brew group.
Clean and reset brew group:
- Open the service door and remove the brew group according to the user manual.
- Rinse the brew group thoroughly under warm water, moving the internal piston and levers to remove coffee residues.
- Allow it to dry completely, then lightly lubricate moving parts with food-safe silicone grease recommended for coffee machines.
- Reinstall the brew group, ensuring it locks fully into place.
Check internal drive:
- If E07 persists, remove the side or rear cover to access the brew group drive motor and gear train.
- Inspect gears for broken teeth and ensure the drive screw or lever moves freely.
- Check the position microswitches or Hall sensors that detect brew group position; verify connectors are secure.
Replace the brew group drive motor, gear set, or position sensor if defective. If mechanical alignment is lost, a service technician may need to recalibrate the mechanism.
Repair Difficulty
Required Part
We may earn a commission from links on this page.