E14 error and the display or buttons do not respond correctly.
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety first: Unplug the coffee maker before removing the control panel.
Dry and reset:
- If the panel has been exposed to steam or cleaning liquids, allow it to dry for several hours.
- Perform a power reset by unplugging the machine for 10 minutes, then reconnecting.
Internal checks (advanced):
- Remove the front fascia to access the user interface (UI) board.
- Check the flat ribbon cable between the UI and main PCB; reseat both ends carefully.
- Inspect for corrosion or moisture on the UI board.
If the UI board is damaged or unresponsive after reseating cables and drying, it will need replacement. Firmware or main PCB issues should be handled by an authorized service center.