Beko
Coffee Circuit Control Fault
Hot water function works, but coffee brewing does not start or stops early.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Brew group not detected, Faulty brew group microswitch, Coffee valve stuck, Software error in coffee program
How to Fix / Troubleshooting
Brew group:
- Remove, clean, and reinstall the brew group, ensuring it locks correctly.
Switches (advanced):
- Access and test the brew group presence switch with a multimeter.
- Check the coffee valve for movement and blockages.
If hot water works but coffee does not, the issue is likely in the brew group detection or coffee valve control and may require part replacement.
Advertisements
Repair Difficulty
Hard