E09
Electrolux
Water Pump / Priming Failure
Machine shows E09; pump is very loud but little or no water reaches the brew group.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Airlock in pump, Failed vibration pump, Blocked inlet filter on water tank, Kinked or pinched inlet hose
How to Fix / Troubleshooting
Safety: Always unplug the machine before removing the water tank or covers.
Basic checks:
- 1. Re-seat water tank: Remove the reservoir, rinse it, and ensure the outlet valve at the bottom moves freely. Reinstall firmly until it clicks.
- 2. Prime the pump: Fill the tank completely. If your model has a hot water function, run it several times to draw water through the system and clear air.
- 3. Check inlet filter: Inspect the small mesh filter at the tank outlet or inside the machine's tank socket. Clean any debris or scale.
Advanced steps:
- 4. Inspect hoses: Remove the cover and check the silicone hose from the tank to the pump for kinks or compression.
- 5. Test pump: Disconnect the outlet hose and place it into a container. Briefly power the pump (via service mode or direct power) to see if it delivers a strong pulsed flow. Replace the pump if weak or silent.
Resolution: If priming and cleaning do not restore normal operation, replace the Ulka-style vibration pump with an Electrolux-specified equivalent.