Jura
Used Coffee Grounds Counter / Sensor Issue
Machine displays 'Empty grounds container' even when it is empty and reinserted
Advertisements
Possible Causes
Grounds container not fully inserted, Dirty or faulty container sensor, Software counter not resetting properly, Broken actuator tab on container
How to Fix / Troubleshooting
Step 1 – Properly reset container:
- With the machine on, remove the drip tray and grounds container.
- Wait 10 seconds, then reinsert both fully until they click.
Step 2 – Clean sensor area:
- Clean the area where the container slides in; remove coffee residues.
Step 3 – Power cycle:
- Turn the machine off and unplug for 5 minutes, then restart.
Step 4 – Inspect container and sensor (advanced):
- Check the container for a broken plastic tab that actuates the sensor; replace container if damaged.
- With housing removed (unplug first), test the sensor or microswitch and replace if faulty.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Used Coffee Grounds Container Sensor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements