Jura
Milk Suction Failure
No milk is drawn from the container, but steam comes out
Advertisements
Possible Causes
Air leak in milk hose connections, Blocked milk suction nozzle, Incorrect assembly of frother parts, Worn internal seals in milk frother
How to Fix / Troubleshooting
Step 1 – Check hose connections:
- Ensure the milk hose is firmly attached to both the milk container and the frother.
- Check for cracks or pinholes in the hose; replace if damaged.
Step 2 – Disassemble and clean frother:
- Take apart the frother and clean all internal channels.
- Pay special attention to the suction nozzle where the milk hose connects.
Step 3 – Check assembly order:
- Reassemble the frother exactly as shown in the manual; incorrect assembly can block suction.
Step 4 – Replace worn parts:
- If suction still fails, internal seals or valves in the frother may be worn; replace the frother head.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Milk Frother Head
Check Price on Amazon