Jura Milk Suction Failure

No milk is drawn from the container, but steam comes out

Advertisements

Possible Causes

Air leak in milk hose connections, Blocked milk suction nozzle, Incorrect assembly of frother parts, Worn internal seals in milk frother

How to Fix / Troubleshooting

Step 1 – Check hose connections:

  • Ensure the milk hose is firmly attached to both the milk container and the frother.
  • Check for cracks or pinholes in the hose; replace if damaged.

Step 2 – Disassemble and clean frother:

  • Take apart the frother and clean all internal channels.
  • Pay special attention to the suction nozzle where the milk hose connects.

Step 3 – Check assembly order:

  • Reassemble the frother exactly as shown in the manual; incorrect assembly can block suction.

Step 4 – Replace worn parts:

  • If suction still fails, internal seals or valves in the frother may be worn; replace the frother head.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Milk Frother Head