Severin Restricted Outlet / Overheating in Thermoblock

Excessive steam and gurgling noises; coffee drips very slowly and is over-extracted.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Partial scale blockage in outlet, Very fine coffee grind, Blocked filter basket holes, Faulty thermostat allowing overheating

How to Fix / Troubleshooting

Safety first: Unplug and allow to cool before cleaning.

  • Use coarser grind: For Severin filter coffee makers, use medium grind, not espresso-fine.
  • Clean filter basket: Soak the metal basket in hot water with mild detergent and scrub the holes with a soft brush.
  • Descale: Run a descaling cycle to clear partial blockages in the thermoblock and outlet.
  • Observe temperature: If water seems excessively hot (lots of steam, burnt smell), the thermostat may be faulty and should be replaced.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Filter Basket and Thermostat
Check Price on Amazon