Amazon Basics
Accessory Power Supply Failure
Attachments (crevice tool, mini motorized head) do not receive power or spin
Advertisements
Possible Causes
Dirty or bent electrical contacts on wand, Broken wires inside wand, Faulty accessory motor, Damaged accessory connector
How to Fix / Troubleshooting
Safety first: Remove the battery and detach all accessories before inspection.
Step-by-step checks:
- 1. Inspect wand contacts: Look at the electrical contacts at both ends of the wand. Clean gently with a dry cloth and ensure they are not bent.
- 2. Test accessory directly: If possible, connect the powered accessory directly to the main body (without the wand) and test. If it works, the wand wiring is suspect.
- 3. Try another accessory: If one powered tool works and another does not, the non-working tool’s motor or connector is likely faulty.
When to stop: Replace the damaged wand or accessory; internal wire repair is usually not practical.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Extension Wand
Check Price on Amazon