Eureka Filter Bypass or Failure

Vacuum runs but blows dust out of the exhaust vent.

Advertisements

Possible Causes

Missing HEPA/post-motor filter, Torn or improperly seated filter, Cracked filter housing, Incorrect aftermarket filter

How to Fix / Troubleshooting

Safety first: Remove the battery before accessing the exhaust filter.

Steps to try:

  • Verify filter presence: Open the exhaust filter cover and confirm the HEPA/post-motor filter is installed.
  • Inspect filter: Look for tears, holes, or separation of the filter media from its frame. Replace if damaged.
  • Check seating: Ensure the filter is oriented correctly and fully seated in its housing so air cannot bypass it.
  • Use genuine parts: Replace with a genuine Eureka filter designed for your model to ensure proper fit and filtration.
Advertisements

Repair Difficulty

Very Easy 1/5

Required Part

HEPA/Post-Motor Filter
Check Price on Amazon

We may earn a commission from links on this page.