E14
Insignia
Attachment Detection / Accessory ID Fault
Vacuum randomly shuts off and shows E14 when switching between attachments.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Dirty or bent accessory ID contacts, Faulty accessory recognition circuit on PCB, Damaged wiring in wand, Non‑compatible powered accessory
How to Fix / Troubleshooting
Safety first: Remove the battery before cleaning contacts or inspecting the wand.
- Clean all contacts: On the main body, wand ends, and powered accessories, clean the metal contacts with a dry cloth. Ensure no debris or corrosion is present.
- Check for bent pins: Carefully straighten any bent pins using non‑metallic tools.
- Test with basic nozzle: Attach only the standard floor nozzle and test. If E14 occurs only with a specific accessory, that accessory may be faulty.
- Inspect wand wiring (advanced): If the error occurs with multiple accessories, the wand’s internal wiring may be damaged and the wand should be replaced.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Extension Wand Assembly
Check Price on Amazon