Parkside Backflow / Check Valve Absence or Failure

Vacuum spits debris back out of the nozzle when turned off

Advertisements

Possible Causes

Overfilled dust container, Blocked cyclone causing reverse airflow, Missing or damaged flap valve in Parkside floor head, Clogged nozzle channel

How to Fix / Troubleshooting

Safety: Remove the battery before cleaning.

  • Empty bin: Ensure the dust container is emptied before it reaches the maximum fill line.
  • Clean cyclone: Remove and clean the cyclone assembly to restore proper separation.
  • Inspect floor head: Check for a rubber flap or valve inside the nozzle. If torn or missing, replace the floor head or valve.
  • Clear nozzle: Remove any debris lodged near the nozzle opening that could be expelled when suction stops.
Advertisements

Repair Difficulty

Very Easy 1/5

Required Part

Floor Nozzle Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements