Accessory Motor Overload / Stall
Vacuum displays E13; mini motorized tool (mattress or pet brush) stops and flashes error.
Advertisements
Possible Causes
Mini brush jammed with hair, Blocked air path in mini tool, Worn accessory motor, Faulty accessory motor driver
How to Fix / Troubleshooting
Safety first: Remove the battery and detach the mini motorized tool from the vacuum.
- Clear jams: Open the mini brush cover and remove the brush roll. Cut away hair and fibers from the brush and end caps.
- Inspect air path: Look through the mini tool's suction channel and remove any blockages.
- Test tool separately: Reattach the mini tool and run the vacuum on low power. If the tool stalls quickly again, the accessory motor may be failing.
- Replace accessory: Replace the complete Mini Motorized Brush Tool if cleaning does not resolve the issue.