E18
Roborock Dustbin Not Detected / Bin Presence Switch Fault

Vacuum shows E18; dustbin icon flashes and unit refuses to start.

Advertisements

Possible Causes

Dustbin not fully seated, Broken dustbin latch, Faulty bin detection microswitch, Damaged bin sensor on PCB

How to Fix / Troubleshooting

Safety first: Turn off and remove the battery before inspecting the bin mechanism.

  • Reseat dustbin: Remove the dustbin and reinstall it firmly until it clicks. Ensure no debris is trapped around the latch.
  • Inspect latch: Check the bin latch for cracks or deformation that prevent full engagement.
  • Check switch actuator: Look for a small plastic tab on the bin that presses a switch inside the body. If broken, the bin may not be detected.
  • Test switch: With the bin removed and battery out, manually press the bin switch (if accessible) and listen for a click. If it does not click, the switch may be faulty.
  • Replace parts: Replace the Dustbin Assembly if the tab or latch is broken. If the switch is defective, replace the Bin Detection Switch or associated PCB.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Dustbin Assembly / Bin Detection Switch
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements