Roborock No Power / Dead Unit

Vacuum will not turn on at all; no lights or response when pressing the trigger.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Completely discharged or failed battery, Faulty power switch or trigger, Blown fuse on main PCB, Defective charger

How to Fix / Troubleshooting

Safety first: Do not attempt to bypass fuses or short battery terminals.

  • Check charger: Plug in the charger and verify its LED status. Try another outlet.
  • Charge fully: Leave the vacuum on charge for at least 3 hours. Look for any LED activity.
  • Test with another battery: If available, try a known-good battery. If the unit powers on, replace the original Battery Pack.
  • Inspect trigger: Ensure the trigger moves freely. If it feels loose or stuck, the internal switch may be broken.
  • Service PCB: If a good battery and trigger do not restore power, the Main Control PCB or internal fuse likely needs professional replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Battery Pack / Main Control PCB
Check Price on Amazon