Possible Causes
Loose battery latch, worn battery contacts, cracked battery housing, internal battery protection tripping due to shock or vibration
How to Fix / Troubleshooting
Safety first: Remove the battery and inspect it before further use.
- Check latch mechanism: Ensure the battery latch moves freely and fully engages. If it does not hold the battery securely, repair or replace the latch.
- Inspect contacts: Look for burn marks or pitting on the battery and vacuum contacts. Clean lightly with a dry cloth; replace components if heavily damaged.
- Test with gentle tapping: With the vacuum running, gently tap the handle. If it cuts out, the battery connection is intermittent and the battery or housing should be replaced.
- Replace worn parts: Install a new battery pack or battery bay/connector assembly if the connection cannot be made reliable.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Battery Connector Assembly
Check Price on Amazon