F5
Sencor
Battery Communication / Identification Error
Vacuum shows F5 and the LED battery indicator behaves erratically (jumps between levels or flashes).
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Non-original battery pack without proper ID chip, Dirty or bent data contacts on battery, Faulty ID circuit in Sencor battery pack, Damaged battery connector on main PCB
How to Fix / Troubleshooting
Safety first: Remove the battery before inspecting contacts.
- Use original battery: Ensure you are using a genuine Sencor battery pack recommended for your model. Third-party packs may not communicate correctly.
- Clean contacts: Gently clean the battery and vacuum contacts with a dry cloth. Do not use abrasive materials.
- Inspect for damage: Look for bent or recessed pins in the battery compartment. If pins are damaged, the main body may need repair.
- Test with another battery: If possible, try another known-good Sencor battery. If F5 disappears, replace the original battery. If F5 remains, the main PCB battery interface is likely faulty and requires technician service.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Battery Connector Assembly
Check Price on Amazon