Sencor Poor Pickup / Brushroll or Nozzle Performance Issue

Vacuum leaves debris on the floor and does not pick up well, especially on carpets.

Advertisements

Possible Causes

Worn brushroll bristles on Sencor floor head, Brushroll not spinning at full speed, Incorrect height setting (if adjustable), Blocked nozzle intake

How to Fix / Troubleshooting

Safety first: Turn OFF and remove the battery before working on the nozzle.

  • Inspect brushroll: Check bristles for wear; if they are very short or uneven, replace the brushroll.
  • Clean brushroll: Remove hair and fibers wrapped around the brushroll and end caps.
  • Check nozzle intake: Look for blockages at the front lip and internal channels of the nozzle.
  • Test brush motor: With the vacuum on (battery reinstalled), briefly observe whether the brushroll spins. If it is slow or intermittent, the brush motor or wiring may need replacement.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Floor Nozzle Brushroll Assembly