Severin No Power / Dead Unit

Vacuum does not turn on at all; no lights, no sound, even with battery installed.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Completely discharged or defective battery pack, faulty power button on handle, broken internal wiring between battery contacts and PCB, failed main control PCB

How to Fix / Troubleshooting

Safety first: Ensure the charger and vacuum are kept away from water and children during troubleshooting.

  • Step 1 – Check battery charge: Place the battery on the original Severin charger. Confirm that the charger LED indicates charging. Allow at least 1–2 hours of charge, then test the vacuum again.
  • Step 2 – Try powering while on charger (if model supports): Some Severin cordless vacuums can run briefly while connected. If it runs only when on the charger, the battery is likely defective.
  • Step 3 – Inspect battery fit: Insert the battery and ensure it clicks firmly into place. A loose battery may not make contact.
  • Step 4 – Check power button: Press the power button firmly and hold for 2–3 seconds. Try multiple times. If the button feels loose, stuck, or does not click, the switch may be faulty.
  • Step 5 – Service if still dead: If there are still no lights or sounds with a known-good battery, the internal wiring or main PCB has likely failed. These components require professional replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Power Button / Main Control PCB