E10
Tower
Floorhead Communication / Power Fault
Cordless vacuum shows E10 and the LED headlight on the motorised floorhead does not illuminate; brush may or may not spin.
Advertisements
Possible Causes
Broken wiring in extension wand, Loose connector between wand and floorhead, Failed LED/PCB in Tower motorised head, Damaged floorhead power pins on main body
How to Fix / Troubleshooting
Safety first: Remove the battery before inspecting electrical connections.
- Step 1 – Check connections: Detach and reattach the wand and floorhead, ensuring each connection clicks firmly into place.
- Step 2 – Inspect contacts: Look at the metal power pins at the base of the main body and at the top of the wand. Clean gently with a dry cloth.
- Step 3 – Wiggle test: With the vacuum running (battery installed, but keep fingers away from moving parts), gently move the wand connection. If the headlight flickers, the wand wiring is likely damaged.
- Step 4 – Test with another wand/head: If available, test with a known‑good Tower wand or floorhead to isolate the faulty component.
- Step 5 – Replace faulty part: Replace the Tower extension wand with wiring loom or the motorised floorhead assembly depending on which fails the tests.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Tower Extension Wand with Wiring Loom
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements