E13
Tristar Severe Airflow Restriction / Filter Blockage

Vacuum runs but suction is very weak; display shows E13 or filter icon; unit may pulse on and off.

Advertisements

Possible Causes

Completely clogged pre-motor filter, Severely blocked cyclone shroud, HEPA exhaust filter saturated with fine dust, Obstruction in wand or hose

How to Fix / Troubleshooting

Safety first: Turn the vacuum OFF and remove the battery pack before disassembling the dust system.

  • Empty and clean dust bin: Remove and empty the dust container. Detach the cyclone assembly and use a soft brush to clean all holes and mesh surfaces.
  • Clean or replace pre-motor filter: Remove the pre-motor filter. Tap it gently to remove dust. If washable, rinse with lukewarm water until clear, then air-dry completely (24 hours) before reinstalling. Replace if damaged or permanently discolored.
  • Service HEPA filter: Remove the HEPA exhaust filter. Tap gently to remove loose dust. Replace if suction remains weak or if the filter is older than the manufacturer’s recommended interval.
  • Check wand and attachments: Look through the wand and any flexible hose for blockages. Use a long rod or broom handle carefully to push out clogs.
  • Reassemble and test: Once all components are clean and dry, reassemble and test. If E13 persists with clear airflow, the pressure sensor or control PCB may be faulty.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Tristar Pre-Motor Filter
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements