Tristar Nozzle LED Circuit / Wiring Fault

LED lights on the floor nozzle flicker or do not turn on, but the brushroll still spins.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose LED connector inside nozzle, Broken wire in nozzle harness, Failed LED board, Damaged connector at wand-to-nozzle joint

How to Fix / Troubleshooting

Safety first: Turn OFF the vacuum and remove the battery pack before opening the nozzle.

  • Check external connection: Ensure the nozzle is fully seated on the wand and that the electrical contacts are clean.
  • Inspect internal wiring (advanced): Remove the nozzle cover and locate the LED board and its wiring harness. Verify that connectors are firmly seated and wires are not pinched or broken.
  • Replace LED board: If the wiring is intact but the LEDs remain off, replace the LED board assembly if available as a separate part. Otherwise, replace the entire nozzle.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Tristar Floor Nozzle LED Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements