Vax
Brush Bar / Floorhead Mechanical Damage
Cordless Vax vacuum makes a rattling or grinding noise from the floorhead when the brush bar is engaged.
Advertisements
Possible Causes
Debris lodged in brush bar housing, Worn or broken brush bar end caps, Damaged brush bar drive gear, Foreign object caught in floorhead wheels
How to Fix / Troubleshooting
Safety first: Turn OFF and remove the battery before working on the floorhead.
- 1. Remove the floorhead and brush bar: Detach the head, flip it over, and remove the brush bar via the side cap or release mechanism.
- 2. Inspect for debris: Remove any stones, coins, or hard objects from the brush chamber and wheels.
- 3. Check end caps and bearings: Spin the brush bar ends by hand. If rough, noisy, or loose, replace the brush bar assembly.
- 4. Inspect drive gear: If accessible, check the drive gear and belt (if fitted) for missing teeth or damage.
Replace the motorised floorhead assembly if internal gears or the brush motor are damaged.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Brush Bar Assembly
Check Price on Amazon
We may earn a commission from links on this page.