E08
Arcelik Low Water Level / Circulation Pressure Error

Dishwasher displays E08 and dishes remain dirty; spray arms may not rotate properly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Partially blocked water inlet system, Clogged filters or sump, Leaking circulation system reducing pressure, Faulty circulation pump

How to Fix / Troubleshooting

Safety first: Turn off power and water supply before removing hoses or panels.

  • Clean filters and spray arms: Remove and wash all filters. Detach spray arms and rinse under running water, clearing any blocked jets with a toothpick.
  • Check water level: Start a program and let the machine fill. Open the door after a few minutes (pause cycle) and check that the water level is just below the door lip. If very low, inspect the inlet filter and hose for blockages.
  • Inspect for leaks: Look under and around the dishwasher for signs of water leakage that could reduce internal pressure. Repair any visible hose or clamp issues.
  • Check circulation pump performance: If water level is correct but spray arms do not spin, the circulation pump may be weak. Access the pump from the bottom, inspect for debris, and test the motor. Replace if necessary.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Circulation Pump Motor
Check Price on Amazon

We may earn a commission from links on this page.