iA0
Electrolux Spray Arm Rotation / Spray Pressure Fault

Dishwasher displays iA0; often related to spray arm or loading issues.

Advertisements

Possible Causes

Blocked lower or upper spray arm jets, Overloaded or incorrectly loaded racks blocking spray arms, Low circulation pump pressure, Debris in sump restricting flow

How to Fix / Troubleshooting

Safety first: Turn off power before removing spray arms or working inside the tub.

  • Check loading: Ensure tall items are not blocking the rotation of the lower, middle, or upper spray arms. Reposition dishes so arms can spin freely.
  • Clean spray arms: Remove the spray arms by unscrewing or unclipping them. Rinse under running water and use a toothpick to clear clogged jets.
  • Clean filters and sump: Remove and clean the filters. Check the sump for food debris that could reduce pump pressure.
  • Test rotation: Manually spin each spray arm to confirm smooth movement. Reinstall and run a short cycle to verify operation.
  • Further diagnosis: If iA0 persists and arms are clear, the circulation pump may be weak and require testing or replacement.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Electrolux Lower Spray Arm
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements