Possible Causes

Stuck or shorted keypad button, Moisture behind control panel, Damaged user interface board, Loose ribbon cable to main control

How to Fix / Troubleshooting

Safety first: Disconnect power before removing the control panel.

  • Power reset: Turn off the breaker for 5 minutes, then restore power to see if the ER code clears.
  • Inspect keypad: Remove the inner door panel and examine the keypad area for signs of moisture, corrosion, or physical damage.
  • Dry and clean: If moisture is present, dry the area thoroughly and check the door vent and gasket for leaks that may allow steam into the control area.
  • Replace UI board: If specific buttons are unresponsive or the ER code persists, replace the user interface control board with the correct Frigidaire part.