E15
Wexiodisk
Rinse Pressure / Flow Fault
E15 is displayed and the machine may stop; often associated with low rinse pressure or poor final rinse coverage.
Advertisements
Possible Causes
Blocked rinse nozzles on spray arms, Partially closed rinse supply valve, Faulty rinse pressure switch, Clogged rinse line filter
How to Fix / Troubleshooting
Safety: Turn off power and water supply before dismantling rinse components.
- Clean rinse arms: Remove the upper and lower rinse arms. Use a small brush or toothpick to clear each nozzle of limescale and debris. Rinse thoroughly.
- Check supply valve: Ensure the external rinse water valve (if separate) is fully open and that the building supply pressure meets Wexiodisk requirements.
- Inspect rinse filter: Some models have an inline rinse filter or strainer. Remove and clean under running water.
- Test pressure switch: If fitted, check the rinse pressure switch for correct operation with a multimeter while applying pressure. Replace if faulty.
After cleaning and checks, run several cycles and confirm that E15 does not reappear and that rinse coverage is uniform.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Rinse Spray Arms
Check Price on Amazon
We may earn a commission from links on this page.