Possible Causes

Drain program set to hold water (tank machines), Partially blocked drain hose, Weak drain pump, Incorrect drain hose height causing siphon issues

How to Fix / Troubleshooting

Safety: Disconnect power before working on the drain system.

  • Check program settings: Some Wexiodisk models allow tank water to be retained. Verify settings and select a program with drain if required.
  • Inspect drain hose routing: Ensure the hose rises to the correct height and then falls to the drain, preventing backflow or siphoning.
  • Clean drain hose: Remove and flush the hose to clear grease and debris.
  • Assess pump performance: If drainage is slow, the pump may be worn or partially blocked. Inspect and replace if necessary.