Wexiodisk Rinse Spray Arm Obstruction

Rinse arms do not rotate properly; dishes at the top or bottom rack are not rinsed well, no error code.

Advertisements

Possible Causes

Blocked rinse nozzles, Scale buildup in rinse arm bearings, Racks or tall items blocking arm rotation, Low rinse pressure

How to Fix / Troubleshooting

Safety: Turn off power and allow the machine to cool before removing arms.

  • Remove and clean arms: Take out upper and lower rinse arms. Clean all nozzles and pivot points with a brush and descaling solution if needed.
  • Check rotation: Refit and spin by hand to ensure free movement.
  • Adjust loading: Avoid placing tall items where they can obstruct arm rotation.
  • Verify rinse pressure: If arms still rotate slowly, check rinse pump and supply pressure.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Rinse Spray Arms
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements