E12
Asko Humidity / Moisture Sensor Circuit Error

Dryer displays E12; may not start or may shut down quickly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted moisture sensor bars, Sensor harness short to ground, Faulty moisture sensor module (if separate), Control board fault

How to Fix / Troubleshooting

Safety first: Unplug the dryer.

Steps to resolve sensor circuit error:

  • Inspect and clean sensor bars: Inside the drum, clean the moisture sensor bars with alcohol to remove conductive residue.
  • Check for shorts: Access the back of the sensor bars and inspect wiring. Ensure no wires are pinched or touching the drum or chassis.
  • Continuity tests: With wires disconnected, verify that each bar is isolated from ground and from each other (infinite resistance). If a bar is shorted to ground, replace the sensor assembly.
  • Module/board check: If wiring and bars are correct, the moisture sensing circuit on the control board may be defective.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Moisture Sensor Assembly
Check Price on Amazon