E01
Dryer will not start; display shows E01 shortly after pressing Start.
Door Lock / Door Switch Fault
E02
Dryer stops shortly after start or will not start; E02 displayed.
Overheating / High Temperature Cut-Out
E03
Dryer runs but clothes remain wet; E03 displayed near end of cycle.
Moisture Sensor / Drying Sensor Fault
E04
Dryer stops mid-cycle and displays E04; may feel very hot inside.
Exhaust Airflow Restriction / Overheat Protection
E05
Dryer will not heat; E05 displayed after a few minutes of running.
Heater Circuit Fault
E06
Dryer drum does not turn; motor hums or stops; E06 displayed.
Drive Motor / Belt Fault
E07
Dryer stops and displays E07; may occur shortly after start.
Motor Overload / Motor Overheating
E08
Dryer will not start; E08 displayed; sometimes accompanied by clicking from control area.
Main Control Board / Relay Fault
E09
Dryer display shows E09; unit may not respond to button presses.
User Interface / Control Panel Communication Error
E10
Dryer shows E10 and stops; often associated with very long drying times.
Inlet Air Temperature Sensor Fault
E11
Dryer shows E11; may stop heating or terminate cycle prematurely.
Exhaust Temperature Sensor Fault
E12
Dryer displays E12; may not start or may shut down quickly.
Humidity / Moisture Sensor Circuit Error
E13
Dryer shows E13; may be associated with internal fan issues on some Asko condenser/heat pump dryers.
Internal Circulation Fan Fault
E14
Dryer displays E14; cycle may not start or may stop unexpectedly.
Water Tank / Condensate Level Error (Condenser/Heat Pump Models)
E15
Dryer shows E15; may be associated with heat pump system on certain Asko models.
Heat Pump System Fault (Heat Pump Dryers)
E16
Dryer displays E16; may not heat properly or may shut down.
Heater Relay / Power Relay Error
E17
Dryer shows E17; may not start or may stop with a beeping alarm.
Door Locking System Error
E18
Dryer displays E18; may be associated with internal temperature safety systems.
Safety Thermostat / Thermal Cut-Out Tripped
E19
Dryer shows E19; may not respond correctly to selected programs.
Program Memory / Configuration Error
E20
Dryer shows E20; may be associated with internal communication between boards on advanced models.
Internal Communication Bus Error
Symptom
Dryer display flickers or resets when starting a cycle.
Power Supply / Voltage Drop Issue
Symptom
Dryer display works but time remaining does not count down correctly; cycle seems to run indefinitely.
Auto-Sense / Moisture Detection Miscalibration
Symptom
Dryer door pops open during cycle, causing the dryer to stop.
Door Latch / Strike Wear
Symptom
Dryer door will not open at the end of the cycle; door appears locked even though the machine is off.
Door Lock Stuck Closed
Symptom
Dryer drum does not turn, but you hear the motor running or humming.
Broken or Slipped Drive Belt
Symptom
Dryer drum light does not turn on when the door is opened, but dryer otherwise works.
Drum Light Circuit Failure
Symptom
Dryer drum turns but there is a loud squealing or screeching noise during operation.
Drum Support / Idler Pulley Wear
Symptom
Dryer emits a burning smell during operation, with or without visible smoke.
Overheating / Lint Ignition Risk
Symptom
Dryer has a musty or moldy odor that transfers to clothes.
Odor / Bacterial Growth
Symptom
Dryer leaks water onto the floor during or after operation (condenser/heat pump models).
Water Leak / Condensate Management Fault
Symptom
Dryer makes a loud thumping or banging noise, especially with larger loads.
Drum Roller Flat Spots / Out-of-Round Drum Support
Symptom
Dryer makes a rattling or clinking noise, especially at certain drum speeds.
Foreign Object in Drum or Blower
Symptom
Dryer powers on but Start button does nothing; display may show normal time but no response.
User Interface Input Failure
Symptom
Dryer runs but clothes come out wrinkled and very hot, even on low heat settings.
Temperature Regulation / Cycling Thermostat Fault
Symptom
Dryer runs but does not heat; clothes remain cold and damp at end of cycle (no error code).
No Heat Condition
Symptom
Dryer runs but there is a low rumbling or grinding noise that gets worse over time.
Drum Bearing / Rear Support Wear
Symptom
Dryer runs for a few minutes then shuts off and will not restart until it cools down.
Motor Overheating / Thermal Protector Tripping
Symptom
Dryer stops mid-cycle and the display is completely blank; power returns after some time.
Overheating Control Board / Power Supply Interruption
Symptom
Dryer takes too long to dry; cycles run much longer than normal and clothes are still slightly damp.
Poor Drying Performance / Extended Dry Times
Symptom
Dryer vibrates excessively or walks across the floor during operation.
Excessive Vibration / Imbalance
Symptom
Dryer will not start at all; no drum movement when Start is pressed, though lights may be on.
No Start Condition